Further information relating to examination of SPD Curves

This web-page is designed to display example spectral distribution curves for tested light sources. For more information relating to the graphing library used in this page see the dygraphs website. For more information about the project in general contact Joseph Padfield.


Calculating the CCT, Duv and CRI from the SPD curve of: Erco Light Board V01 72808.000 (Min): LED - 3000K

  • Display Results
  • Graphs

Illuminant: Erco Light Board V01 72808.000 (Min): LED - 3000K

CCT: 2862K | Duv: 0.0033 | CRI: 92.71

CRI Calculations

CRI - Calculation Summary


IlluminantBlack Body
X108.3258109.7662
Y100100
Z31.111935.7518
u0.25460.2557
v0.35260.3494

TCS01 TCS02 TCS03 TCS04 TCS05 TCS06 TCS07 TCS08 TCS09 TCS10 TCS11 TCS12 TCS13 TCS14
ReferenceU39.3916.98-14.38-41.19-35.84-23.3116.8845.39128.5627.90-50.89-34.0835.26-10.64
V2.398.4814.297.59-2.65-13.29-11.65-7.78-1.1718.386.44-24.056.007.84
W62.9561.1461.0958.0059.0558.1960.5063.8846.7482.8448.0324.1481.5739.65
IlluminantU37.8815.73-15.37-40.34-34.20-22.1615.7941.75119.6024.93-50.58-30.2133.80-11.39
V2.548.7114.578.10-2.63-13.88-12.17-8.03-0.7718.807.02-25.936.187.96
W62.9661.2561.2558.0859.0357.9760.2463.4745.7883.0248.1123.3981.6339.74
ΔEUVW1.511.281.041.001.641.311.243.679.023.000.664.371.480.76
Ri93.0594.1395.2395.4292.4793.9794.3083.1158.5286.1996.9779.9293.1996.49