Further information relating to examination of SPD Curves

This web-page is designed to display example spectral distribution curves for tested light sources. For more information relating to the graphing library used in this page see the dygraphs website. For more information about the project in general contact Joseph Padfield.


Calculating the CCT, Duv and CRI from the SPD curve of: Erco Opton Floodlights V01 72644.00: LED - 3000K

  • Display Results
  • Graphs

Illuminant: Erco Opton Floodlights V01 72644.00: LED - 3000K

CCT: 2987K | Duv: 0.0012 | CRI: 92.19

CRI Calculations

CRI - Calculation Summary


IlluminantBlack Body
X107.7546108.2749
Y100100
Z37.376839.0065
u0.25060.251
v0.34890.3478

TCS01 TCS02 TCS03 TCS04 TCS05 TCS06 TCS07 TCS08 TCS09 TCS10 TCS11 TCS12 TCS13 TCS14
ReferenceU39.1817.11-13.78-40.70-35.42-23.4016.2044.25127.7028.36-50.52-33.8335.22-10.27
V2.809.3115.408.08-2.98-14.34-12.51-8.17-0.3620.156.82-25.346.718.42
W62.7761.0561.1258.1759.2358.3460.4563.7046.1682.6948.2824.4981.4139.68
IlluminantU37.5316.08-14.29-39.26-33.65-22.4814.6640.18118.1925.75-49.37-30.4333.73-10.76
V3.069.5915.768.39-3.19-15.13-12.89-8.270.1020.667.29-28.246.948.56
W62.8361.1861.2658.1559.1458.0760.2063.3045.1882.9148.1723.7581.5239.76
ΔEUVW1.671.080.641.481.791.241.614.099.582.671.244.521.510.52
Ri92.3295.0597.0493.1991.7994.3092.6281.2055.9487.7094.2979.2093.0497.62