Make | Name | Date | Type | CCT (K) | CRI | TM-30 (Rf) | TM-30 (Rg) | Duv | Source | RE% |
---|---|---|---|---|---|---|---|---|---|---|
Calculated Data | EES | 2010-11-11 |
TS |
5455 | --> | -0.0044 |
NG |
157.23 |
||
GE | Vio/G4/Module/3.6W/741 | 2010-11-09 |
LED |
4121 [3500] | --> | 0.0071 |
NG |
127.47 |
||
Leelium | Daylight MSR | 2011-09-07 |
HMI |
5657 | --> | -0.0047 |
NG |
112.95 |
||
GE | F40W/AD | 2010-11-09 |
FL |
5670 [6500] | --> | 0.0025 |
NG |
111.75 |
||
Solux | 12V Diachroic | 2010-11-09 |
TH |
4484 [4700] | --> | -0.0019 |
NG |
109.46 |
||
Pro-Lite | Daylight SRI-30W Par 30 | 2011-01-20 |
CFL |
6154 | --> | 0.0090 |
NG |
101.3 |
||
Nature | Studio2 Filtered Daylight | 2010-11-09 |
DL |
5595 | --> | 0.0058 |
NG |
100 |
||
Erco | Eclipse - Blue Lens | 2010-11-09 |
TH |
4057 | --> | 0.0022 |
NG |
91.64 |
||
Endura | OT16-3101-WT MR16 | 2011-08-08 |
LED |
6335 [6336] | --> | 0.0014 |
GCI |
90.99 |
||
Willard | LEDGO CN-600SC | 2012-12-06 |
LED |
5915 | --> | 0.0001 |
NG |
90.96 |
||
Toshiba | E-Core Par30s 23Deg | 2013-05-31 |
LED |
5830 [6500] | --> | 0.0007 |
NG |
88.98 |
||
Osram | Photonbeard Dulux L 954 | 2012-12-06 |
FL |
5312 | --> | 0.0098 |
NG |
88.16 |
||
Cooper | DL11-WS-CW | 2010-11-09 |
LED |
5173 | --> | 0.0033 |
NG |
82.75 |
||
Osram | Dulux L 80W/840 2G11 | 2010-11-11 |
FL |
4112 [4000] | --> | 0.0015 |
NG |
82.59 |
||
Philips | TLD 36W/95 | 2010-11-09 |
FL |
4305 [5000] | --> | 0.0035 |
NG |
81.97 |
||
FEM | LED | 2012-12-06 |
LED |
5054 | --> | 0.0002 |
NG |
81.9 |
||
Unknown | Test Lamp | 2013-01-23 |
LED |
5054 | --> | 0.0002 |
NG |
81.9 |
||
Philips | 50Par30L-WFL40 | 2011-01-20 |
TH |
3415 | --> | 0.0015 |
NG |
80.23 |
||
LSI | LumeLEX 2040-C4M2-6S | 2011-03-22 |
LED |
4114 [4000] | --> | -0.0044 |
NG |
75.45 |
||
Cooper | RWD1-RWS-CW | 2010-11-09 |
LED |
4924 | --> | 0.0035 |
NG |
75.26 |
||
GE | FC8T9/CW | 2011-08-08 |
FL |
4154 [4100] | --> | 0.0137 |
NG |
72.01 |
||
Osram | 12V Diachroic | 2010-11-09 |
TH |
2964 | --> | 0.0003 |
NG |
68.9 |
||
Concord | 2627632 MK41 | 2011-08-08 |
TH |
2934 [3000] | --> | 0.0013 |
NG |
67.58 |
||
DAL | Baltic 64005 | 2011-09-07 |
TH |
2799 | --> | -0.0008 |
NG |
67.35 |
||
Sylvania | TrueAim-Titan MR16 35° | 2011-01-20 |
TH |
2909 | --> | 0.0003 |
NG |
67.28 |
||
Photon Star | CS5 NIC-WW-SB-60-BW | 2010-11-09 |
LED |
3378 [3000] | --> | -0.0077 |
NG |
64.23 |
||
Erco | Eclipse - Clear Lens | 2010-11-09 |
TH |
2802 | --> | 0.0008 |
NG |
63.87 |
||
Philips | Philips 50W MR16 | 2011-08-08 |
TH |
2729 [2703] | --> | 0.0010 |
GCI |
62.86 |
||
GE | EYC 71W MR16 | 2011-08-08 |
TH |
2708 [2709] | --> | 0.0013 |
GCI |
62.58 |
||
GE | Par38 (11878) | 2013-05-30 |
TH |
2605 [2850] | --> | 0.0009 |
NG |
62.2 |
||
Luxina | EXZ-CG-M250 MR16 24° | 2011-01-20 |
TH |
2970 | --> | 0.0041 |
NG |
62.13 |
||
GE | Par 38 80W Flood | 2010-11-09 |
TH |
2613 | --> | 0.0009 |
NG |
62.02 |
||
Osram | Par 38 120W | 2010-11-09 |
TH |
2594 | --> | 0.0007 |
NG |
62.01 |
||
GE | Par 38 80W Spot | 2010-11-09 |
TH |
2596 | --> | 0.0008 |
NG |
61.8 |
||
Erco | Optec Spotlights 72078.000 14W (SN: 1122CH0023) B1 | 2011-09-07 |
LED |
3377 [3200] | --> | -0.0001 |
NG |
60.82 |
||
Synergy | 1003605 S12 WW MR16 | 2011-08-08 |
LED |
3406 [3400] | --> | -0.0050 |
GCI |
60.75 |
||
Mike Stoane | Track Type X (Min) | 2013-05-30 |
LED |
3138 [3000] | --> | -0.0005 |
NG |
60.31 |
||
Mike Stoane | Track Type X (Mid) | 2013-05-30 |
LED |
3131 [3000] | --> | -0.0006 |
NG |
60.11 |
||
Mike Stoane | Track Type X (Max) | 2013-05-30 |
LED |
3129 [3000] | --> | -0.0007 |
NG |
60.02 |
||
Erco | Optec Spotlights 72078.000 14W (SN: 1121CH0138) B2 | 2011-09-07 |
LED |
3405 [3200] | --> | 0.0012 |
NG |
59.92 |
||
Erco | Optec Spotlights 72078.000 14W (SN: 1121CH0180) B2 | 2011-09-07 |
LED |
3409 [3200] | --> | 0.0018 |
NG |
59.59 |
||
Erco | Optec Spotlights 72078.000 14W (SN: 1121CV0470) B1 | 2011-09-07 |
LED |
3357 [3200] | --> | 0.0007 |
NG |
59.4 |
||
Concord | Beacon Muse 2052867 (Narrow) | 2012-12-06 |
LED |
3117 [3000] | --> | -0.0038 |
NG |
59.1 |
||
Synergy | 1003607 NF34 WW MR16 | 2011-08-08 |
LED |
3303 [3300] | --> | -0.0046 |
GCI |
59.06 |
||
Erco | Optec Spotlights 72078.000 14W (SN: 1121CV0476) B2 | 2011-09-07 |
LED |
3429 [3200] | --> | 0.0017 |
NG |
59.05 |
||
Erco | Optec Test Lamp | 2010-11-09 |
LED |
3034 [3200] | --> | -0.0010 |
NG |
58.91 |
||
LSI | LumeLEX 2040-C3M2-6S | 2011-03-22 |
LED |
2966 [3000] | --> | -0.0026 |
NG |
58.91 |
||
Erco | Optec Spotlights 72078.000 14W (SN: 1121CH0202) B2 | 2011-09-07 |
LED |
3336 [3200] | --> | 0.0015 |
NG |
58.2 |
||
Synergy | 1003606 NF24 WWMR16 | 2011-08-08 |
LED |
3320 [3300] | --> | -0.0030 |
GCI |
58.04 |
||
Concord | Beacon Muse 2052867 (Wide Beam) | 2012-12-06 |
LED |
3047 [3000] | --> | -0.0035 |
NG |
57.9 |
||
Sylvania | Concord 2048806 | 2011-03-22 |
LED |
3010 [3000] | --> | -0.0010 |
NG |
57.73 |
||
Sylvania | Concord 2048794 | 2011-03-22 |
LED |
3008 [3000] | --> | -0.0004 |
NG |
57.22 |
||
GE | Standard Tungsten | 2010-11-09 |
TH |
2313 | --> | 0.0002 |
NG |
57.04 |
||
Synergy | 1003608 NF50 WW MR16 | 2011-08-08 |
LED |
3200 [3200] | --> | -0.0022 |
GCI |
56.18 |
||
CRS | CRS SP12 WW MR16 | 2011-08-08 |
LED |
3048 [3049] | --> | -0.0006 |
GCI |
55.91 |
||
Sylvania | UltraLED Par 30LN 40° | 2011-01-20 |
LED |
3056 [3000] | --> | 0.0000 |
NG |
55.23 |
||
Philips | EnduraLED MR16 B | 2011-09-14 |
LED |
3084 | --> | -0.0003 |
NG |
54.86 |
||
LEDnovation | LED-PAR38-90-1WD-INF | 2011-08-08 |
LED |
2966 [2968] | --> | -0.0012 |
GCI |
54.55 |
||
Sylvania | UltraLED MR16 25° | 2011-01-20 |
LED |
3182 [3000] | --> | 0.0035 |
NG |
54.53 |
||
Cooper | DL11-WS-WW | 2010-11-09 |
LED |
3087 | --> | 0.0008 |
NG |
54.52 |
||
GE | Par 30 | 2010-11-09 |
LED |
3065 | --> | -0.0002 |
NG |
54.21 |
||
Philips | EnduraLED MR16 | 2011-01-20 |
LED |
3065 [3000] | --> | 0.0003 |
NG |
54.13 |
||
Erco | Opton Floodlights V01 72644.00 | 2013-05-31 |
LED |
2987 [3000] | --> | 0.0012 |
NG |
53.72 |
||
LSI | LumeLEX 2040-C2M2-6S | 2011-03-22 |
LED |
2710 [2700] | --> | -0.0003 |
NG |
53.51 |
||
Erco | Light Board V01 72808.000 | 2013-05-31 |
LED |
2946 [3000] | --> | 0.0019 |
NG |
53.24 |
||
MSI | iPAR3830021D | 2011-08-08 |
LED |
2946 [2948] | --> | -0.0002 |
GCI |
53.21 |
||
Philips | BBG480 25 | 2010-11-09 |
LED |
2666 [2700] | --> | -0.0028 |
NG |
52.16 |
||
GCI Filter | Thin-Film Mark 2 on MR16 | 2011-08-08 |
TH |
2862 [2620] | --> | 0.0028 |
GCI |
52.09 |
||
Cooper | RXD2-RWS-WW | 2010-11-09 |
LED |
3088 | --> | 0.0031 |
NG |
52.04 |
||
Cooper | RXD1-RWS-WW | 2010-11-09 |
LED |
3038 | --> | 0.0027 |
NG |
52.02 |
||
Hoffmeister | LED-104-471 | 2013-05-31 |
LED |
3174 [3000] | --> | 0.0025 |
NG |
51.81 |
||
Erco | ERCO Large Flood 1046780000 | 2013-05-31 |
LED |
2905 | --> | 0.0026 |
NG |
51.74 |
||
Erco | Light Board V01 72808.000 (Min) | 2013-05-31 |
LED |
2862 [3000] | --> | 0.0033 |
NG |
50.74 |
||
Sylvania | NF25 Par-38 | 2011-08-08 |
LED |
2663 [2664] | --> | -0.0018 |
GCI |
50.61 |
||
Lamina | WW-NB MR16 | 2011-08-08 |
LED |
3224 [3236] | --> | 0.0008 |
GCI |
50.58 |
||
Philips | Philips Par38 | 2011-08-08 |
LED |
2659 [2660] | --> | -0.0019 |
GCI |
50.54 |
||
Solais | LR38 | 2011-08-08 |
LED |
2674 [2675] | --> | -0.0013 |
GCI |
50.49 |
||
Philips | MASTER LEDspot MV Dimmable | 2013-05-30 |
LED |
2785 [2700] | --> | 0.0013 |
NG |
49.7 |
||
Endura | OT16-3301-WW MR16 | 2011-08-08 |
LED |
2857 [2859] | --> | 0.0000 |
GCI |
48.82 |
||
CREE | LRP-38 (Dupe) | 2013-05-30 |
LED |
2716 [2700] | --> | 0.0017 |
NG |
48.07 |
||
Lamina | True Color MR16 | 2011-08-08 |
LED |
2724 [2700] | --> | -0.0008 |
GCI |
47.52 |
||
CREE | LRP-38 | 2011-08-08 |
LED |
2616 [2620] | --> | 0.0018 |
GCI |
46.23 |
This web-page is designed to display relative exposures totals for the various light sources included in this system. Please read the appropriate sections on the information page, here and here, for an explanation of how these values have been calculated. For more information about the project in general contact Joseph Padfield.
Displaying the CCT, CRI, TM30 Rf & Rg, Duv and relative spectral sensitivity normalised exposure values, calculated as a percentage of filtered daylight: